EV Fire Blanket

Poseidon supplies EV fire blankets with high-silica and high-temperature fiberglass fabric options, silicone or graphite coatings, and sizes for vehicle coverage. Standard sizes include 6 m × 8 m, 6 m × 9 m, and 8 m × 9 m; custom sizes are available for bulk and OEM requirements.

An EV fire blanket is intended to help limit fire spread and heat exposure to nearby objects. Covering a vehicle can reduce visible flaming while battery thermal runaway and gas release continue. With active battery involvement, flammable gases can accumulate beneath the blanket and present an explosion hazard; indoor or confined-space deployment can increase that risk.

Select the blanket by vehicle dimensions, fabric and coating, handling weight, thermal test documentation, and the intended professional response procedure. Blanket use requires trained personnel and does not replace incident controls, protective equipment, or respiratory protection.

EV Fire Blanket Specifications

EV fire blankets are specified for vehicle fire limitation as part of a professional response plan. The blanket size must cover the intended vehicle with enough allowance for its height and shape; a nominal size alone does not establish suitability for every car, motorcycle, or bus.

Poseidon offers high-silica or high-temperature fiberglass fabrics with silicone and graphite coating options. Material selection, thickness, fabric weight, total handling weight, and storage format should be matched to the intended application. Listed material temperature values are configuration options; exposure duration and test conditions determine what those values mean.

For a bulk or OEM quotation, provide:

  • Vehicle dimensions and required blanket size
  • Preferred fabric, coating, thickness, and handling weight
  • Order quantity, destination market, and packaging or branding requirements
  • Required thermal and mechanical test reports, identification, and use instructions

After exposure to heat, contamination, or damage, continued use depends on the product instructions and condition assessment. Reuse should not be assumed solely because the fabric appears intact.

For other applications, compare the available fire blanket types.

  • Fabric Options: High-silica fabric and high-temperature fiberglass configurations.
  • Coating Options: Silicone and graphite options for the selected blanket construction.
  • Size Options: Standard 6 m × 8 m, 6 m × 9 m, and 8 m × 9 m sizes, with custom dimensions available.
  • Handling Specifications: Select thickness, fabric weight, total blanket weight, and storage format for the intended response program.
  • Bulk and OEM Supply: Specify quantity, configuration, branding, packaging, and required documentation when requesting a quote.
  • Professional EV Response Programs: Blanket procurement for trained fire-service or industrial response teams where vehicle fire limitation is included in the response procedure.
  • Charging and Fleet Operations: Select blanket dimensions and storage arrangements for the vehicles managed by the site and its professional response plan.
  • Vehicle Service and Recovery: Review handling, contamination, inspection, and post-incident requirements before specifying a blanket for service or recovery operations.

These purchasing contexts do not establish safe blanket deployment in every location. Active battery fires can continue to release hazardous gases, and indoor or confined-space use can present a significant explosion hazard.

Parameter Metric Imperial
Material High-silica fabric, high-temp fiberglass High-silica fabric, high-temp fiberglass
Coating Silicone, Graphite Silicone, Graphite
Thickness 0.45mm, 0.75mm 0.018in, 0.03in
Weight 480g/m², 580g/m², 800g/m² 14.2oz/yd², 17.1oz/yd², 23.6oz/yd²
Total Weight 26.2kg, 33.5kg, 42kg 57.8lbs, 73.9lbs, 92.6lbs
Material Heat-Resistance Options 550°C, 1000°C, 1400°C 1022°F, 1832°F, 2552°F
Standard Sizes 6m×8m, 6m×9m, 8m×9m 19.7ft×26.2ft, 19.7ft×29.5ft, 26.2ft×29.5ft
Specification Reference DIN SPEC 91489 DIN SPEC 91489

DIN SPEC 91489:2024-11 describes requirements for fire limitation blankets used with electric vehicles. It is a specification for the blanket and does not establish that battery thermal runaway stops after deployment.

For procurement, request the thermal and mechanical test report, product identification and traceability, handling instructions, and any after-use restrictions for the exact blanket configuration.